Adam,Rouilly  /  Products  /  Male & Female Catheterisation Simulator Set, Light
Skills and Features

Skills

  • Allow demonstration and practice in urinary catheterisation without embarrassment or discomfort to the patient
  • Catheterisation simulators are useful for anatomical identification and demonstration of perineal care

Features

Life/form® Female Catheterisation Simulator

  • Constructed with a bladder reservoir, patient urethra, and a valve simulating the internal urethral sphincter
  • The normal feeling of resistance and pressure will be experienced as a catheter is passed through the urethra, past the sphincter, and into the bladder
  • When the catheter enters the bladder, artificial urine (water) will flow from the catheter just as in a real patient, and the cuff must be completely deflated before the catheter is removed
  • Improper use of a Foley can result in damage to the simulator
  • This simulator is the torso of a middle-aged woman with thighs abducted for proper position during catheterisation
  • The external genitalia and perineum are molded in lifelike form
  • The labia minora can be spread apart naturally to reveal the clitoris, urethral opening, and vaginal introitus

Life/form® Male Catheterisation Simulator

  • A lubricated catheter can be inserted in the urethral orifice, passed through the urethra, and into the bladder
  • When the bladder is successfully entered, artificial urine (water) will flow from the catheter
  • The student will feel the normal restrictions caused by the mucosal folds, bulbous urethra, and the internal urethral sphincter, just prior to entrance into the bladder
  • The experience teaches proper positioning and movement of the penis to allow the catheter to pass easily with a minimum of discomfort to the patient
  • Just as in a real patient, the cuff must be completely deflated before the catheter is removed
  • Improper use of a Foley catheter can result in damage to the simulator, just as when using a Foley catheter with a real patient
Additional Information

Includes

  • AN856 Female Catheterisation Simulator, Light
  • AN855 Male Catheterisation Simulator, Light

Important

  • Fluid supply stand not included
  • 16 Fr. Silicone Foley catheter can be used if extreme care is taken to inflate the cuff only when it is in the proper position
  • Just as in a real patient, the cuff must be completely deflated before the catheter is removed
  • Improper use of a Foley can result in damage to the simulator, just as when using a Foley catheter with a real patient

 

Manufacturer

Nasco Healthcare

Spares and Repairs

Related Spares and Repairs

SKUProduct NamePriceAction
AN1127Foley Catheter, 16 Fr, 5 CcPrice on requestView Product
AN1128Foley Catheter, 16 Fr, 5 CcPrice on requestView Product
AN985LubricantPrice on requestView Product